AC-201
ACMDC-1001
AC-201
ACMDC-1001 & AC-201 Manual Download PDF
L-6000
ACMDC-1001
ACMDC-1001 Manual Download PDF
L-6000
L-6000 Manual Download PDF

AC650 SERVO
CONTROLLER CARD

The AC650 servo control card is used for linear positioning and hydraulic servo valve control.  It can be used as a stand alone controller or can be used in multiple axis systems.

AC650 Manual Download PDF

AC650

FIRMWARE FEATURES:

  • Isolated 8 inputs and 8 outputs (5-32VDC)
  • Non-volatile memory storage so no battery backup is required.  
  • High-speed  RS485/RS422 SDLC serial port. Baud rates of 1.2 m standard
  • Low-speed RS-422 serial port accessible through a 6 pin phone jack. Baud rates of 2400 to 19.2k.
  • Digital interface to MTS(R) Temposonics(R) linear transducers.
  • Provides +/-  0-100 mA current output for Servo valves.
  • Has +/- 10vdc output capability.
  • Dip switch auto-null selection.
  • Addressable Dip switch settings for up to 8 axes.
  • Red status LED’s mounted on the face of the board.
  • Uses Euro-style connector for easy installation in single or multiple card racks.
  • Can be interfaced to RS-232 serial communication port through inexpensive converter.

SOFTWARE FEATURES:

  • Custom programs embedded on UV EPROM.
  • Programs written to interface card control through a phone jack to dummy computer terminals.
  • Programs written to interface card to PC’s through high-speed serial port.
  • Personal Computer (PC) High-speed communications board available.
  • Data presented in thousandths of inches or centimeters.
  • Programs written for special applications.

POWER SPECIFICATIONS:

  • +5vdc @ .5 amps
  • +15vdc @ .1 amps*
  • -15vdc @ .1 amps

*When using TransTerm 5 Computer terminal, +15vdc .5 amps is required.

OPERATING TEMPERATURES

  • -40 TO 150 deg.F ( -40 to 66 deg. C.)
AC651

AC651 SERVO CONTROLLER CARD FEATURES AND ELECTRICAL SPECIFICATIONS

The AC651 servo control card is used for linear positioning and hydraulic servo valve control.  It is used with PLC’s as a external servo controller.  A PLC can control 1-8 axes per bank.

AC651 Manual Download PDF

FIRMWARE FEATURES:

  • Isolated 17 inputs  (5-32VDC)
  • Non-volatile memory storage so no battery backup is required.
  • High-speed  RS485/RS422 SDLC serial port. Baud rates of 1.2 m standard
  • Low-speed RS-422 serial port accessible through a 6 pin phone jack. Baud rates of 2400 to 19.2k.
  • Digital interface to MTS(R) Temposonics(R) linear transducers.
  • Provides +/-  0-100 mA current output for Servo valves.
  • Has +/- 10vdc output capability.
  • Dip switch auto-null selection.
  • Addressable Dip switch settings for up to 8 axes per bank.
  • Red status LED’s mounted on the face of the board.
  • Uses Euro-style connector for easy installation in single or multiple card racks.
  • Can be interfaced to RS-232 serial communication port through inexpensive converter.

SOFTWARE FEATURES:

  • Custom programs embedded on UV EPROM.
  • Programs written to interface card control through a phone jack to dummy computer terminals.
  • Programs written to interface card to PC’s through high-speed serial port.
  • Personal Computer (PC) High-speed communications board (PC1) available.
  • Data presented in thousandths of inches or centimeters.
  • Programs written for special applications.

POWER SPECIFICATIONS:

  • +5vdc @ .5 amps
  • +15vdc @ .1 amps*
  • -15vdc @ .1 amps

*When using TransTerm 5 Computer terminal, +15vdc .5 amps is required.

OPERATING TEMPERATURE:

  • -40 TO 150 deg. F ( -40 to 66 deg. C.)

AC700 TEMPOSONIC(R) INTERFACE CARD

The AC700 Temposonic(R) card provides multiple digital interfaces for MTS(R) I, MTS(R) II, LP and LH Temposonics probes.  Through the use of user installable jumpers, the interface card meets all interfacing needs for MTS(R) linear transducers.

AC700 Manual Download PDF

AC700

FIRMWARE FEATURES:

  • +5vdc regulator installed on board.
  • Capable of interrogating transducers > 100ft.
  • Heavy duty Entrelec connectors used  for high vibration environments.
  • Board thickness is .120” to provide for solid non flexing in high g-force environments.
  • All firmware soldered directly to board.
  • User installable jumpers for configuring the board. 
  • Board jumpers include 1-8 Recirculations, external/internal interrogation,  MTS(R) I and MTS(R) II, jumper configuation for MTS(R) II probes using DPM’s.
  • Red Power status and Yellow Run status LED’s mounted on the board and located on a printed operating/troubleshooting truth table overlay.
  • Servo valve connections on board terminals.
  • Labeled terminal connections.
  • Installation and operation manual provided with each unit.
  • Timing selection for probes 0 to 48” and 48” to 170”.
Power Requirements:
AC700 Power Requirements
External +5V Supplied No External +5V
Voltage Current Tolerance Voltage Current Tolerance
+15 VDC 50 mA +14.25 to +15.75 VDC +15 VDC 275 mA +14.25 to +15.75 VDC
-15 VDC 25 mA -14.25 to -15.75 VDC -15 VDC 25 mA -14.25 to -15.75 VDC
+5 VDC 200 mA +4.75 to +5.25 VDC
TemposonicsTM Probe Power Requirements
MTS I Probes MTS II Probes
Voltage Current Tolerance Voltage Current Tolerance
+15 VDC 50 mA +14.25 to +15.75 VDC +15 VDC 150 mA +14.25 to +15.75 VDC
-15 VDC 20 mA -14.25 to -15.75 VDC -15 VDC 100 mA -14.25 to -15.75 VDC
+12 VDC 25 mA +4.75 to +5.25 VDC

OPERATING TEMPERATURE:

  • -40 TO 150 deg.F ( -40 to 66 deg. C.)
Contact Us